Siemens to supply sf 6-free GIS for BKK Nett in Norway

Nov 27, 2020 · Europe | November 27, 2020. Norway, Bergen: Siemens Energy Management has secured an order from Bergenshalvøens Kommunale Kraftselskap (BKK Nett) in Norway to supply the world’s first sf 6-free gas insulated switchgear (GIS) with clean air and vacuum interruption systems for a voltage level of up to 145 kV. The switchgear is part of the Koengen substation in Bergen, which shall supply electricity from renewable energy sources to Norway’s largest cruise ship seaport.Get price

Siemens receives order for worldfirst sf 6-free gas

SF 6 -free gas-insulated switchgear (GIS) for 145 kV, 40 kA, 3,150 A. Combination with low power instrument transformers (LPIT) ensures a compact design. Siemens Energy Management received an order from Bergenshalvøens Kommunale Kraftselskap (BKK Nett) in Norway to supply the worldfirst sf 6-free GIS with "clean air" and vacuum interruption systems for a voltage level of up to 145 kilovolts (kV).Get price

Siemens to supply Sulfr hexafluoride-free gas insulated switchgear for BKK

Siemens Energy Management has secured an order from Bergenshalvøens Kommunale Kraftselskap (BKK Nett) in Norway to supply the worldfirst insulating gas-free gas insulated switchgear (GIS) with clean air and vacuum interruption systems for a voltage level of up to 145kV. Image: 8VN1 Blue GIS up to 145kV with Low Power Instrument Transformers (LPIT).Get price

Alternatives for Sulfr hexafluoride | 2020 | Siemens Energy Global

In most of the worldsubstations sulfur hexafluoride (gaz sf6) is the insulating gas of choice. Still, due its potential climate impact, industry is looking for environmentally friendly solutions – and they have options. In Bergen, a transformer station supplies electricity to Norwaylargest port for cruise ships.Get price

Siemens receives order for world first sf6 gas-free gas-insulated

Siemens Energy Management has received an order from Bergenshalvøens Kommunale Kraftselskap (BKK Nett) in Norway to supply the world’s first insulating gas-free GIS with “clean air” and vacuum interruption systems for a voltage level of up to 145 kilovolts (kV).Get price

smart grid Companies and Suppliers in Norway | Environmental

DILO has been a specialist in sf 6 gas handling for more than 50 years. With approx. 320 employees and more than 70 representatives worldwide, DILO is a key technology partner for switchgear manufacturers and power utilities around the world.Get price

Medium Voltage blue GIS | Systems | Siemens Global

At this yearHannover Messe, Siemens will present another medium-voltage switchgear that doesn't require sulfur hexafluoride (Sulfr hexafluoride) as the insulating gas: the 8DAB 12. The system uses clean air consisting only of the natural constituents of ambient air as the insulating gas.Get price

Power Transmission | Offerings | Siemens Energy Global

Additionally, we are expanding our portfolio of gaz sf6-free transmission products. We open the door to a world of opportunity by adopting and fostering digital solutions. Through our digitalization transformation, we use advanced intelligence that enhances productivity, optimizes performance, and protects your assets with extended cybersecurity.Get price

Hints for maintaining type SP sf6 gas power circuit - Siemens USA

follow all safety instructions contained herein, on the equipment, or in siemens’ other instuctions. Major inspection Major internal inspections require the removal of gas from the circuit breaker to determine the condition of the interrupters, contacts, and other internal components.Get price

insulating gas Transmitter - Draeger

sf6 gas Transmitter Product Information, en-master. The insulating gas transmitter is ideally suited for the gas measurement of sulfur hexafluoride in the field of high voltage engineering. The transmitter can be used both as a gas leak detector and to monitor the gas quality in gas-insulated switchgear (GIS) or transformers. DownloadGet price

Assetguard GDM - Siemens

house gases such as sf 6, with the target of reducing emissions to 0,5% per annum. As a result, gas density monitoring is essential to improve leakage visibility, notwithstanding the superior perfor-mance of modern GAS Insulated Switchgear (GIS). Siemens Assetguard GDM takes care of the actual Sulfr hexafluoride gas condition and support managing a more dynamicGet price

Transformer dew point measurement insulation - Siemens USA

Prior to final oil filling, the dew point measurement technique is widely used to estimate moisture content of dry insulation inside of power transformers. Experience strongly suggests that the technique provides an accurate and reliable method of moisture estimation in a gas space. When used with proper understanding, it can be a very useful tool.Get price

sf 6 circuit breaker maintenance - Siemens USA

Sulfr hexafluoride circuit breaker technology was developed in the early 1960s to meet the growing demands for reliable high-voltage circuit breakers with interrupting mediums. The industry was ready for an alternative to the traditional mediums of mineral oil and/or air.Get price

EU Report Highlights Sulphur Hexafluoride Countdown

For decades, sf 6 has been used in switchgear as an insulation material and current-breaking medium. On Sept. 30, 2020, the EU released a detailed report (1) outlining alternatives to sulphur hexafluoride (Sulfr hexafluoride) for use in switchgear and related equipment. The report also extensively covers market impact and cost issues.Get price

Sulfr hexafluoride gas in medium-voltage switchgear - Siemens USA

In this issue, we discuss the use of insulating gas (sulfur hexafluoride) gas in medium-voltage switchgear. gaz sf6 has been widely used in high-voltage circuit breakers for decades, but its use in medium-voltage is relatively recent. In the medium-voltage arena, SIemens uses Sulfr hexafluoride gas in the load interrupting switch and switch-disconnector in SIMOSEC metal-enclosed load interrupter switchgear rated up to 27.6 kV. Characteristics and propertiesGet price

sf 6 Transmitter - Draeger

The sf6 gas transmitter is ideally suited for the gas measurement of sulfur hexafluoride in the field of high voltage engineering. The transmitter can be used both as a gas leak detector and to monitor the gas quality in gas-insulated switchgear (GIS) or transformers.Get price

Wind farm places the first insulating gas-free Siemens high-voltage

Press Release 24 April 2018, updated 25 April 2018 Energy Management Erlangen Wind farm places the first Sulfr hexafluoride-free Siemens high-voltage switchgear (GIS) into operation Siemens supplied four bays of the 8VM1 gas-insulated Sulfr hexafluoride-free high-voltage switchgear (GIS) – which has a capacity of 72.5 kilovolts (kV) – to Siemens Gamesa Renewable Energy.Get price

sf 6 Gas Density Switches for High Voltage Circuit - Solon MFG

Sulfur Hexafluoride (Sulfr hexafluoride) Temperature-Compensated (TC) Pressure Switches Solon Manufacturingtemperature-compensated Sulfr hexafluoride gas density monitoring pressure switches are an economical and reliable way to monitor Sulfr hexafluoride gas density and leakage over a wide temperature range.Get price

Siemens supplies sf 6-free high-voltage switchgear for English

Siemens will supply 102 Sulfr hexafluoride-free, gas-insulated 8VM1 high-voltage switchgear (GIS) to Siemens Gamesa by the middle of next year. The switchgear will protect each wind turbine individually against overloads and short-circuits and make it possible to supply electricity reliably and without interruption.Get price

Process Gas Chromatographs | Yokogawa America

Process gas chromatography is used for separating and analyzing chemical compounds in the gas phase of industrial processes. Since the mid-twentieth century, the gas chromatograph has made a name for itself as a do-all analytical instrument with analysis capabilities ranging from percent level to ppm.Get price

Sf6 purity analyzers in switchgears - Switchgear Content

May 20, 2020 · sf6 gas gas plays a key role in switchgears and the percentage of gas purity has a direct effect on the switching. Commercially, Sulfr hexafluoride is supplied in pressurized bottles or liquid tanks. The gas of these bottles has a minimum degree of purity of 99.9% and may possess the following impurities according to IEC 60376: carbon tetrafluoride (CF4) <0.03%.Get price

MV GIS ring main unit SafeRing - Gas insulated switchgear

Medium voltage (MV) insulating gas-insulated ring main unit for secondary distribution up to 40.5 kV, 630A SafeRing is a ring main unit (RMU) for the secondary distribution network. It is available in 18 different configurations suitable for most switching applications within the range from 6 to 40.5 kV.Get price

Solvay Special Chemicals

Fig. 11 Gas insulated line for sf6 gas / N2 mixture in a tunnel 245 – 550 kV (Siemens, Germany) Fig. 10 Polyethylene coated GIL system for direct burial 245 – 550 kV (Siemens, Germany) Fig. 9 gaz sf6 / N2-membrane-separation plant with condenser unitGet price

HV Remote Monitoring System Provides sf 6 Gas Emissions for

Test and Measurement; HV Remote Monitoring System Provides Sulfr hexafluoride Gas Emissions for 38kV-and-Above Circuit Breakers. ABB has introduced a remote monitoring solution for any OEM circuit breakers filled with sulfur hexafluoride (sf6 gas) gases, the Circuit Breaker Sentinel, or CBS-F6 condition-based monitoring solution.Get price

Siemens develops Sulfr hexafluoride-free gas-insulated medium-voltage

This type-tested system is used to switch high currents at the primary distribution level. The single-pole encapsulated 8DAB 12 is a Sulfr hexafluoride-free medium-voltage switchgear in the Siemens blue GIS portfolio. Switches and switchgear that use insulating gas as the insulating, switching, and extinguishing gas remain an important part of the Siemens portfolio.Get price

Analyzers Check Sulfr hexafluoride Gas Quality | TD World

DILO Armaturen und Anlagen GmbH has brought a new generation of “sf6 gas Multi-Analyser” multiple measuring devices to market that allow the sf 6 gas quality to be checked easily in accordance with the (EU) F-Gas Regulation and IEC Standard 60480 (reuse specifications).Get price

Siemens Receives Order for WorldFirst Sulfr hexafluoride-free Gas-insula

Nov 07, 2018 · Siemens Receives Order for WorldFirst Sulfr hexafluoride-free Gas-insulated Switchgear With "clean Air" and Vacuum Switching Technology for 145 kV Siemens Energy Management received an order from Bergenshalvøens Kommunale Kraftselskap (BKK Nett) in Norway to supply the worldfirst gaz sf6-free GIS with "clean air" and vacuum interruption systems for aGet price

Multi-function Meter Determines Sulfr hexafluoride Gas Moisture | TD World

Test and Measurement; Multi-function Meter Determines sf6 gas Gas Moisture. Dilosf 6 Multi-function meter from Filtration Solutions can be used to determine and store the volume percentage as well as the moisture of sf6 gas gas from a single test session.Get price

Gas-Insulated-Substations insulating gas gas handling

Sep 26, 2011 · IEC 62271-203 High-voltage switchgear and controlgear – Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (09/2011) Örequired leakage rate <0.5% / year / gas compartment tt f th td i 01%/ / t t ¾Extreme low emissions protect the environment state-o - e-art design <0.1% / year / gas compartment Axial directionGet price